Thickness is measured at a place
Glove thickness is the single-wall thickness of the glove film. United States specification sheets usually give it in mil, a thousandth of an inch, or in millimetres. An inch is exactly 25.4 mm, so 1 mil is 0.0254 mm [1]. Useful anchors: 0.05 mm is about 2.0 mil, 0.08 mm about 3.1 mil, and 0.10 mm about 3.9 mil.
Manufacturers measure thickness at specific locations, usually the fingertip and the palm and sometimes the cuff. The fingertip is usually the thickest point and the figure brands lead with [2]. A “4 mil” claim with no location tells you little, so compare fingertip with fingertip and palm with palm.
Read the value type
Specification sheets state thickness in different ways: as a minimum (“finger min 0.10 mm”), a typical value, a nominal value with a tolerance (“0.08 plus or minus 0.02 mm”), or a range (“4 to 6 mil at fingertips”) [3]. A minimum and a typical value are not comparable. The measured value also depends on the instrument. ASTM’s method for measuring rubber dimensions notes that the pressure of the measuring foot significantly affects thickness readings on soft materials [4].
Weight is grams per glove
Weight is the mass of one glove, usually for size M. It reflects all the material in the glove, its length, its size and how the film is distributed, so two gloves with the same fingertip thickness can weigh different amounts. A 16 inch glove can weigh more than twice as much as a 12 inch glove of the same film [5]. There is no valid formula that turns grams into mil. A listing that calls a weight “equivalent to” a thickness is mixing two different properties.
What the standard sets, and what it leaves open
As quoted in manufacturers’ FDA 510(k) summaries, the ASTM specification for nitrile exam gloves (D6319) sets a minimum single-wall thickness of 0.05 mm, about 2 mil, at the palm and finger. The specification for vinyl exam gloves (D5250) sets 0.08 mm, about 3.1 mil [6]. So a 3 mil and a 6 mil nitrile glove can both meet ASTM D6319. Thickness differences between products are product choices, not grades. FDA’s glove guidance also advises against puffery such as “extra thick” and favors stated measurements [7].
Thicker is not the same as tested
Protection against specific hazards is tested separately. Chemotherapy drug resistance, for example, is tested under ASTM D6978, and FDA cleared chemotherapy-tested gloves include products built to the 0.05 mm minimum [8]. Check the test and its results, not the thickness.
How GTDI shows thickness
Every glove listing shows thickness at each location the manufacturer states, with the value type and both units. Where the manufacturer states no location, the row is left out rather than guessed. We publish no weight-to-thickness conversions and use no words like “extra thick”. The manufacturer’s specification sheet, with its date, comes with your quote.
Sources
- NIST, “SI Units, Length” (undated page; accessed Oct 4, 2026). https://www.nist.gov/pml/owm/si-units-length
- Manufacturers’ exam glove product pages stating finger, palm and cuff values (undated pages; accessed Oct 4, 2026).
- Manufacturers’ nitrile exam glove data sheets and catalogs on file with GTDI (dated 2026 where dated; accessed Oct 4, 2026).
- ASTM D3767-03(2020), Rubber, Measurement of Dimensions (store page updated Feb 24, 2020; scope summary).
- A manufacturer’s product page comparing the weight of its 12 inch and 16 inch exam gloves (undated page; accessed Oct 4, 2026).
- FDA-hosted 510(k) summaries for nitrile exam gloves (cleared Mar 16, 2023 and Jul 20, 2026) and vinyl exam gloves (cleared Feb 6, 2023, Mar 25, 2023 and Aug 28, 2025), with values as quoted by manufacturers under ASTM D6319-19 and D5250-19.
- FDA, Medical Glove Guidance Manual (Jan 2008).
- FDA-hosted 510(k) summary for chemotherapy-tested nitrile gloves (cleared Jul 20, 2026).
This guide is general information for supply planning. Your clinical, safety and compliance teams set your facility's policies. Reviewed October 5, 2026.